Cable loss

How much the coax swallows on the way to the antenna, for common cable types and any frequency. Plus what an SWR at the antenna costs on top and how long ฮป/4 is in this cable.

Cable loss

From cable type and frequency, instead of hunting for the number in the datasheet. The values are rounded guide figures.

How the page calculates

  • a(f) = k1 ยท โˆšf + k2 ยท f (dB per 100 m, f in MHz)
  • k1 and k2 from the datasheet values at 100 and 1000 MHz
  • With SWR s: ฯ = (s โˆ’ 1) / (s + 1), ฮฑ = 10^(a/10), total = 10 ยท log10((ฮฑยฒ โˆ’ ฯยฒ) / (ฮฑ ยท (1 โˆ’ ฯยฒ)))

The loss of a line grows with the square root of frequency through skin effect and linearly with it through dielectric losses. Two datasheet values are enough to find both parts, and in between the curve matches the datasheet to within a few tenths.

With a mismatch, the wave runs through the cable several times and is attenuated every time. That's why a long cable flatters the SWR reading: what the antenna reflects is attenuated again on the way back, and less of it reaches the transmitter.

Cable data the calculator uses

CableZ (ฮฉ)Velocity factor dB/100 m at 100 MHzdB/100 m at 1000 MHz
RG174/U500,6633120
RG316500,702585
RG58 C/U500,661663
RG223500,6612,547
H155500,798,430
Aircell 5500,829,433
RG213/U500,66727
Aircell 7500,836,121,5
Aircom Plus500,854,515,4
H2000 Flex500,834,314,4
Ecoflex 10500,854,414,7
LMR-400500,853,913
Ecoflex 15500,863,110,2
RG59 (75 ฮฉ)750,661145
RG11/U (75 ฮฉ)750,664,517
Ladder line 450 ฮฉ4500,9114

Rounded guide values from datasheets. Your cable's datasheet is what counts.

Related terms

Velocity factor
factor between free-space wavelength and physical length; RG58 has 0.66, one metre takes 5.05 ns in it, try it out under /leitung
SWR
standing wave ratio, a measure of the match between cable and antenna

Related

Power budget SWR and return loss